'A ceiling mounted radial fan with duct exhaust to enable removal of steam and odours direct to atmosphere, as required by the Building Code of Australia.'
ROOF SPACE CONDITIONS CAN AFFECT THE HEALTH OF AN ENTIRE HOME.
Traditional round ceiling exhaust fans in bathrooms and laundries deposit steam and odours direct into roof cavities. Steam can condense forming water which penetrates the ceiling lining and insulation. This can result in damp, and hence less efficient insulation, and mould growth in ceilings.
STANDARDS FOR MECHANICAL VENTILATION
There are two standards that cover the requirements for mechanical ventilation of bathrooms and laundries. These are the Building Code of Australia and AS1668.2. The BCA through adherence to AS1668.2., requires that all steam and odours from a home should be exhausted direct to atmosphere, not deposited in a roof cavity. Many councils now enforce this standard with new housing where sarking is used. AS1668.2 specifies the minimum ventilation requirements for bathrooms, toilets and laundries.
This is:
Toilets: 25 litres per sec.
Bathrooms: 25 litres per sec.
Laundry - 20 litres per sec.
STEAMaway Warranty
CSR Edmonds warrants this product when used on domestic premises for 2 years against defects in workmanship, parts or mechanical failure.
SPECIFICATIONS
Exhaust rate - 45 litres per sec.
Power - 23 watt
Speed - 1200RPM
Noise - 45db
Weight - 1.5kg
Mount dimensions (mm) - 205W x 205L x 160H
Warranty - 2 years.
Self mounted spring clips.
OPERATION
Product comes with a 100mm spigot (150mm attachment available) to enable ducting to eaves or roof. Radial fan design is ultra efficient for removal of dense steam.
A gravity shutter prevents back draughting or insect penetration when fan is not operating.
Compact design is ideal for recessed ceiling mounting where limited space is available.
Available in square diffuser only.
Related Products:
| Ducting Kits for SteamAway |